ISOTECH laboratories Inc. World Class Laboratory. Worldwide Service.
FAQ
High-Precision Isotopic Analysis
217-398-3490
energyecologicalpharmaceutical
274spacer

section photo


Analytical Services > View by Sample Type > Gas > Mudgas > MG-1

Compositional | Natural Gas | Bacterial Gas | Dissolved Gas

MG-1: Level 1 Mudgas Analysis

Applications: Useful during the drilling of oil and gas wells to differentiate biogenic and thermogenic methane, and to provide information on maturation levels and migration barriers.

Minimum hydrocarbon concentrations: CH4 must exceed 500ppm.

Analyses includes: Gas chromatographic measurement of the concentrations of N2, O2+Ar, CO2, CO, CH4, C2H4, C2H6, C3H6, C3H8, iC4H10, nC4H10, iC5H12, nC5H12, and C6+, and determination of the δ13C of CH4 by compound specific GC-C-IRMS (gas chromatography-combustion-isotope ratio mass spectrometry)

Expected Turnaround Time:
Standard Service 5 business days
Rush Service* 1-2 business days
*Advance arrangements required for RUSH SERVICE. Extended analyses and large groups of samples (>200) may require more time.

 

 

whitespacer


Need sampling products?
See our containers developed specifically for mudgas testing.
IsoTubes | IsoJars

 
spacer
 © 2020 Stratum Reservoir (Isotech) 1308 Parkland Court | Champaign Illinois 61821